LEAD ISOTOPIC RATIO MEASUREMENTS USING ICP-QMS
Abstract
Isotopic ratio (IR) measurement is a widely used method for tracing the source and pathways of various elements in the environment. Lead is present in four natural isotopes, 208Pb (52.4%), 206Pb(24.1%), 207Pb(22.1%) and 204Pb (1.4%). Only 204Pb isotope is primordial, the othes are final products of decaying thorium and uranium radioactive isotopes. Because of this, the ratio of 208Pb, 206Pb and 207Pb is not constant over the earth (within a given timeframe), making possible to trace the lead from a specific sample, according to its isotopic ratio. Measuring isoptic ratio of lead requires a sensitive instrument, since differences between isoptes are very small. A standard quadrupole, single collector ICP-MS can be tuned for proper IR measurements, if very precise measurements are not required. Also, a fast analysis is preferred when handling large volumes of samples every day. For a single collector quadrupole, the worst part is that it reads the signal from different isotopes sequentially, thus little change in plasma parameters can affect the RSD of the measurements up to a value that becomes unpractical for use. Hence, a good statistics is need and this can be achieved by increasing the reading time, or the concentration of the sample, but both methods have their limits. A standard mass tuning of the spectrometer is required. We’ve also optimized total reading time, concentration, sweeps, dwell time and the DRC-specific RPq parameter (proportional with the q parameter from the Mathieu equation for stability trajectory inside a quadrupole) and finally obtained decent RSD values that are sufficient in marking the difference between samples coming from different sources. Our RSD values (0.02% – 0.10%) are not as accurate as the one obtained by TIMS technique, but are much more cost effective and samples requires no special treatment before the analysis. NIST 981 (natural lead) standard reference material was used during analyze as a standard and a verification element. For environment tracing isotope ratio measurements, single collector, qadrupole based ICP-MS can be a fast and not that expensive solution, if RSD smaller than 0.02% are not expected.Authors who publish with this journal agree to the following terms:
a) Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
b) Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
c) Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).